INPUT CONNECTORS
03.03
01/2011 We reserve the right to make technical changes.
0033
www.ahlborn.com
High-precision measuring operations using inexpensive standard sensors -
thanks to multi-point correction
LLiinneeaarriizzaattiioonn aanndd ccoorrrreeccttiioonn ooff nnoonn--lliinneeaarr sseennssoorrss
LLiinneeaarriizzaattiioonn aanndd ccoorrrreeccttiioonn aatt oovveerr 3300 ppooiinnttss --
ppeerrffoorrmmeedd bbyy tthhee uusseerr -- wwiitthhoouutt ffuurrtthheerr
pprroocceessssiinngg oonn tthhee PPCC
Although special-purpose sensors with a non-
linear output can usually be connected to e
xisting
measuring systems, the lack of linearization in the
sensor’s output signal means that the measured
value will need subsequent correction to make it at all
usable. AHLBORN now offers customers a revolutionary
new feature - also available with hand-held devices. An
option is now available allowing the user to perform
linearization and multi-point correction on ALMEMO
®
measuring instruments. Not only all the relevant sensor
characteristics but also the linearization or multi-point correction
data are saved in the patented ALMEMO
®
connector. The measuring
instrument automatically recognizes each sensor that is connected to it and
shows the appropriate measured values precisely in its display.
SSeennssoorr--ssppeecciiffiicc lliinneeaarriizzaattiioonn ddaattaa ccaann bbee ssaavveedd bbyy tthhee uusseerr iinn tthhee ccoonnnneeccttoorr iittsseellff..
Thanks to further development of the flexible and intelligent ALMEMO
®
connector it is now possible to save
complex tables for linearization or multi-point correction - all in the connector itself. For the user this means that it
is now also possible to connect sensors with a non-linear output. The device displays measured values already in
linearized form; this ensures that the whole process can be monitored right from the outset. A further advantage
is the enormous saving in time when evaluating special measuring operations of this nature. For each sensor the
linearization data is saved in the connector; then as soon as the sensor is plugged into the measuring instrument this data is
loaded automatically. The linearization table is buffered in the main working memory on the device for the period of the
measuring operation in question or for as long as the sensor remains connected. With effect from the ALMEMO
®
2690-8 the
user can use this “KL” option to program linearization processes of this nature quickly and easily. Individual linearization
processes can be applied in the voltage, current, resistance, or frequency ranges. On request - or for other devices - readily
pre-programmed connectors can be obtained from the factory. Various already implemented special-purpose linearizations
are also available.
HHiigghh--pprreecciissiioonn mmeeaassuurriinngg ooppeerraattiioonnss -- tthhaannkkss ttoo mmuullttii--ppooiinntt ccoorrrreeccttiioonn
A sensor’s output signal can also be corrected at various specific points. Inexpensive standard sensors made by third-party
manufacturers can be calibrated. Deviations are then saved in the sensor connector as fine corrections. This can be
performed either by users themselves or on request in advance at the factory - for example for temperature calibrations. It is
now possible to save not only previous characteristics but also over 30 correction points - all in the connector itself.
PPrrooggrraammmmiinngg vviiaa ssooffttwwaarree
In the AMR-CONTROL software package the
measuring protocol for a multi-point correction or a
linearization table can be transferred to a table of
reference points. O
ver 30 such reference points are
possible. During a measuring operation the
measured values between these are interpolated on
a linear basis. The AMR-CONTROL software is
included with all our instruments free-of-charge.
SSyysstteemm rreeqquuiirreemmeennttss
Connector - the new generation (code “E4”)
For evaluation purposes : ALMEMO
®
devices in version V6
(2690-8, 2890-8, 8590, 8690, 5690, 2390-8, and 2390-5/S)
For user-defined programming : Option “KL” with devices
2690-8, 2890-9,8590, 8690, and 5690